Effect of geometric and physical parameters on resonant frequencies of ultrasonic vibrations of elastic and piezoelectric element system<

https://doi.org/10.23947/1992-5980-2017-17-4-5-13

Abstract

Introduction. Resonance frequencies of the longitudinal oscillations are investigated for a system consisting of diverse geometrical and physical elements - piezoceramic, elastic, and acoustic ones. The results are compared in COMSOL and ACELAN packages. The dependence of the first eigenfrequency value on the geometric parameters is evaluated. The dynamic viscosity effect on the longitudinal oscillations FRF is studied. Materials and Methods. The system of elastic and acoustic elements which allows describing the operation of an ultrasonic cutting device is selected for the study. The oscillator is a piezoelectric transducer which oscillates in thickness. An oscillation concentrator and a rod element are specified as elastic elements. They are made from stainless steel. The cutting element simulator is acoustic fluid. Modal and harmonic analysis of a complex system consisting of diverse physical elements is carried out. Research Results . Axisymmetric and three-dimensional finite-element models of the investigated system are constructed. Various types of curvature and thickness of the link with changeable surface shape are proposed for the oscillation concentrator. The first eigenfrequencies of the longitudinal vibrations of the rod element contacting with the acoustic liquid are obtained. Good agreement with the results of the ACELAN finite-element package is established. The amplitude-frequency characteristics of the end oscillations near the first resonance frequency are obtained. It is notable that the acoustic medium viscosity has little effect on the oscillation amplitude of the elastic rod, and does not affect the resonance frequency at all. Discussion and Conclusions . Harmonic and modal analysis has shown that the high-frequency longitudinal vibrations of the rod element depend significantly on the dissipation factor of the elastic elements, and depend weakly on the viscosity of the contacting acoustic medium. The results obtained may be of interest under designing ultrasonic cutting medical devices.

About the Authors

Alexander S. Skaliukh
Southern Federal University
Russian Federation


Tatyana E. Gerasimenko
Southern Federal University
Russian Federation


Pavel A. Oganesyan
Southern Federal University
Russian Federation


Anna A. Solovieva
Southern Federal University
Russian Federation


References

1. Loshchilov, V.I., Volkov, S.M. K voprosu o mekhanizme ul'trazvukovoy rezki biologicheskikh tkaney. [Revisiting mechanism of ultrasonic cutting of bio-tissues.] Trudy MVTU im. Baumana, 1973, no. 165, pp. 29–33 (in English).

2. Akopyan, V.B., Yershov, Y.A. Ul'trazvuk v meditsine, veterinarii i biologii. [Ultrasound in medicine,veterinary science, and biology.] Shchukin, S.I., ed., 2nd revised and enlarged ed. Moscow: Yurayt, 2017, 223 p. (in English).

3. Dubrovskiy, V.I., Fedorova, V.N. Biomekhanika. [Biomechanics.] Moscow: VLADOS-press, 2003, 672 p. (in English).

4. Carovac, A., Smajlovic, F., Junuzovic, D. Application of Ultrasound in Medicine. Acta Informatica Medica, 2011, no. 19 (3), pp. 168–171.

5. Dong, S. Review on piezoelectric, ultrasonic, and magnetoelectric actuators. Journal of Advanced Dielectrics, 2012, vol. 2, no. 1, pp. 1230001–1230019.

6. Liu, D.-K.-C., Friend, J., Yeo, L. A brief review of actuation at the micro-scale using electrostatics, electromagnetics and piezoelectric ultrasonics. Acoustical Science and Technology, 2010, no. 31 (2), pp. 115–123.

7. Skaliukh, A., Li, G. The general theory of polarization of ferroelectric materials. Advanced Materials. Manufacturing, Physics, Mechanics and Applications. Cham: Springer, 2015, vol. 28, pp. 393–412.

8. Vykhodtseva, N.I., Hynynen, K., Damianou, C. Pulse duration and peak intensity during focused ultrasound surgery: theoretical and experimental effects in rabbit brain in vivo. Ultrasound in medicine & biology, 1994, vol. 20, iss. 9, pp. 987–1000.

9. Duck, F.-A. Physical properties of tissue: a comprehensive reference book. London: Academic Press, 1990, 336 p.

10. Belokon, A.V., Nasedkin, A.V., Soloviev, A.N. Novye skhemy konechnoelementnogo dinamicheskogo analiza p'yezoelektricheskikh ustroystv. [New schemes of finite element dynamic analysis of piezoelectric devices.] Journal of Applied Mathematics and Mechanics, 2002, vol. 66, no. 3, pp. 491–501 (in English).


Review

For citations:


Skaliukh A.S., Gerasimenko T.E., Oganesyan P.A., Solovieva A.A. Effect of geometric and physical parameters on resonant frequencies of ultrasonic vibrations of elastic and piezoelectric element system<. Vestnik of Don State Technical University. 2017;17(4):5-13. (In Russ.) https://doi.org/10.23947/1992-5980-2017-17-4-5-13